top products features new V3

Product Overview

Our PLUS+1 Inverter family:

Type

Nom.
Voltage

   [V]

Nom.
Current
S2-2 min.
[Arms]
Cont.
Current

[Arms]
Boost 
Curr.
10 Sec.
[Arms]
Heat Sink
Types
available
Size
LxWxH_P/
LxWxH_Fx
[mm]
MI01 small MI01-S-24/80 24 80 40 90    P     165x140x70
MI01-S-48/60 48  60 40 65
 MI02-S-24/160 24  160 80 180 P 165x140x70
MI02-S-48/120 48   120 70 130
 F500042 Inverter MI03 cut small MI03-S-24/240 24 240 120 260 P/FH/FV 140x200x90
140x200x110
MI03-S-48/180 48 180  100 200
MI03-X1-80/80 80 80 40 90
 F500043 Inverter MI04 cut small MI04-S-24/300 24 300  150 330 P/FH/FV 140x200x95
140x200x115
MI04-S-48/300 48 300 150  330
  F301647 InverterMI06 24-4001 small MI06-S-24/400 24 400 200 420 P/FH/FV

140x200x100
140x200x
120

MI06-S-48/400 48 400  200 420
  MI08 small MI08-S-24/550 24 550  275 600 P/FH/FV 150x225x100
150x225x120
MI08-S-48/550 48 550 275 600
MI08-S-80/300 80 300 150 330
MI08-S-80/400 80 400 200 440
MI08-S-96/300 96 300 150 330
MI08-S-96/400 96 400 200 440
 F500009 Inverter-MI20-S-80 650P small   MI20-S-80/650 80 650 325 715 P/FV   280x280x100
280x280x141
MI20-S-80/1000 80 1000 500 1100
MI20-S-96/650 96 650 325 715
MI20-S-120/750 120 750 375 820

P = Plate   FH= Horizontal Fins,   FV = Vertical Fins
S = Single Inverter for one AC motor
X1=Single Inverter with reduced Interface

MIxx-S inverter offer a total of 24 I/Os. Thereof, 10 can be configured as per your desire
MIxx-X1 inverter offer a total of 18 I/Os. Thereof, 5 can be configured as per your desire
 

  •   Default
      Config.
      Number

        Max. 
     Number
         Reconfigurable
                    into
    Digital Input 8 15  2 x DIN with
    Pull-up Resistor
    Analog Input unipolar 0..10V 1   n.a. 
    Analog Input bipolar ± 10V 2   n.a.
    Digital Output 2A 5  8 DIN (4) /
    PWM Out (5)
    Digital Output 2A for
    safety relevant components
    1   DOUT / DIN /
    PWM Out Safety
    Current controlled output 0..2A 1    DOUT / DIN /
    PWMOUT
    Current controlled output 0..2A for
    safety relevant components
    1   DOUT Safety / DIN /
    PWM OUT Safety
    Motor Temperature Sensor 1   n.a.
    Incremental Encoder 1 2*) n.a.
    Encoder Power Supply 13V 1   n.a.
    Sensor Power Supply 10V 1   n.a.
    CAN Interface 1   n.a.

    *) Second Enconder uses 2x DIN with Pull-up Resistor, for reduced performance only.
  •   Default
      Config.
      Number

        Max. 
     Number
          Reconfigurable
                    into
    Digital Input 8 10  2 x DIN with
    Pull-up Resistor
    Analog Input unipolar 0..10V 1   n.a. 
    Analog Input bipolar ± 10V 2   n.a.
    Digital Output 2A 2   DIN (1) /
    PWM Out (2)
    Digital Output 2A for
    safety relevant components
    0 n.a.
    Current controlled output 0..2A 0   n.a.
     
    Current controlled output 0..2A for
    safety relevant components
    1   DOUT Safety / DIN /
    PWM OUT Safety
    Motor Temperature Sensor 1   n.a.
    Incremental Encoder 1 2*) n.a.
    Encoder Power Supply 13V 1   n.a.
    Sensor Power Supply 10V 1   n.a.
    CAN Interface 1   n.a.

    *) Second Enconder uses 2x DIN with Pull-up Resistor, for reduced performance only.

Partners SME 3

                   www.danfoss.com                                                                                     www.sme-group.com                                                                                     www.enics.com